Thank you for using our products.
INSTALLATION INSTRUCTIONS
AUDIBLE HORN STROBE TWO WIRE APPLIANCES
(WALL MOUNT VERSIONS)
Use this product according to this instruction manual. Please keep this instruction manual for future reference.
GENERAL:
DMP’s Audible Horn Strobe Appliances require only 2-wires for operation of the horn and strobe appliance and provide a selectable
continuous or Code 3 Horn tone and continuous strobe when connected directly to the Fire Alarm Control Panel (FACP). They can
also provide a synchronized Code 3 horn tone and synchronized strobe when used in conjunction with a Sync Module (831) or Dual
Sync Module (832). They are the ideal choice for applications where the audible silence feature is required. The Audible Horn Strobe
Appliances are UL Listed under Standard 1971 for Signaling Devices for the Hearing Impaired and UL Standard 464 for Audible
Signal Appliances. The 15 candela wall mounted strobes are listed at 15 candela under UL Standard 1971 and meet 75 candela
intensity on axis with low current draw. They are listed for indoor use only and equipped with a Horn Strobe Mounting Plate (823)
that can be mounted to single-gang, double-gang, 4” backbox, 100mm European backbox or SHBB surface backbox (See Mounting
Options). These strobe models are Listed for wall mounting only. The Audible Horn Strobe Appliances use a Xenon flashtube with
solid state circuitry enclosed in a rugged Lexan lens to provide maximum visibility and reliability for effective visible signaling.
Audible Horn Strobe Appliances can be field set for High (HI) or Low (LO) dBA sound output.
These strobe models are designed for use with either filtered DC (VDC) or unfiltered Full-Wave-Rectified (VRMS) input voltage. All
inputs are polarized for compatibility with standard reverse polarity supervision of circuit wiring by a FACP.
NOTE: All CAUTIONS and WARNINGS are identified by the symbol
. All warnings are printed in bold capital letters
WARNING: PLEASE READ THESE INSTRUCTIONS CAREFULLY BEFORE USING THIS PRODUCT. FAILURE
TO COMPLY WITH ANY OF THE FOLLOWING INSTRUCTIONS, CAUTIONS AND WARNINGS COULD RESULT IN
IMPROPER APPLICATION, INSTALLATION AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY
SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE AND SERIOUS INJURY OR DEATH TO YOU
AND/OR OTHERS.
SPECIFICATIONS:
Table 1: UL Ratings
Models Nominal Rated Strobe
Voltage Voltage Range Candela
(VDC/VRMS) (VDC/VRMS) (cd)
803 12 10.5-15.6 15*
* 15cd models are UL Listed for 15cd and meet 75cd on axis.
Table 2A: dBA Sound Output
Description Volume Reverberant Per UL 464 Anechoic dBA
10.5VDC 12.0VDC 15.6VDC 10.5VDC 12.0VDC 15.6VDC
Low 73* 76 76 82 84 86
Continuous Horn High 82 82 85 87 89 91
Low 67* 70* 70* 82 84 86
Code 3 Horn High 76 76 79 87 89 91
2841 E. Industrial Drive, Springfield, MO 65802-6310 800-641-4282
WARNING: AUDIBLE HORN STROBE APPLIANCES SET ON LOW dBA DO NOT MEET THE 75dBA MINIMUM
UL REVERBERANT SOUND LEVEL REQUIRED FOR PUBLIC MODE FIRE PROTECTION SERVICE (NOTED BY *
Downloaded from: http://www.guardianalarms.net
Page view 0
1 2 3 4 5 6 7

Summary of Contents

Page 1

Sheet 1 of 7,167$//$7,21#3;6;7; ;56#$8',%/(#+251#6752%(Thank you for using our products.INSTALLATION INSTRUCTIONSAUDIBLE HORN STROBE TWO WIRE APP

Page 2

P83848 ASheet 2 of 7IN TABLE 1). THIS SETTING IS ACCEPTABLE ONLY FOR GENERAL SIGNALING (NON-FIRE ALARM) USE. USETHE “HIGH” dBA SETTING WITH THIS TON

Page 3

P83848 ASheet 3 of 7LIGHT DISTRIBUTION PER UL 1971:Table 4: Horizontal and Vertical PlaneAngle Horizontal Vertical(in deg.) UL Min. Typ. 15cd* UL Min

Page 4

P83848 ASheet 4 of 7Figure 2: Jumper plug settings for High dB and Code 3. Figure 3: Jumper plug settings for Low dB and Continuous Horn.Figure 4: Jum

Page 5

P83848 ASheet 5 of 7MOUNTING OPTIONS:CAUTION: The following figures show the maximum number of field wires (conductors) that can enter the backbox us

Page 6

P83848 ASheet 6 of 7CAUTION: Check that the installed product will have sufficient clearance and wiring room prior to installing backboxes andconduit

Page 7 - Limitation of Liability

P83848 ASheet 7 of 7IMPORTANT: READ SEPARATE "GENERAL INFORMATION" SHEET FOR INFORMATION ON THE PLACEMENT,LIMITATIONS, INSTALLATION, FINAL